Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Langmuir ; 35(5): 1421-1429, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30056712

RESUMO

Degradable metallic stents, most commonly composed of Mg-based alloys, are of interest as an alternative to traditional metallic stents for application in cardiac and peripheral vasculature. Two major design challenges with such stents are control of the corrosion rate and acute presentation of a nonthrombogenic surface to passing blood. In this study, several types of sulfobetaine (SB)-bearing biodegradable polyurethanes were developed and assessed as physical, chemical, and combination-type coatings for a model degradable Mg alloy, AZ31. For physical coatings, poly(ester sulfobetaine)urethane ureas, PESBUUs were synthesized using variable monomers that allowed the incorporation of a varying extent of carboxyl groups. Introduction of the carboxyl groups was associated with faster polymer degradation time. Simple physical coating of PESBUUs reduced macro- and microscopic thrombogenic deposition together with good stability of the coating attachment compared to a control coating of polylactic- co-glycolic acid. For PESBUUs incorporating carboxyl groups (PESBUUs-COOH), these groups could be converted to siloxane groups (PESBUUs-Si), thus creating polymers that could be surface reacted with the oxidized or phytic acid treated AZ31 surface. Chemical (silanization) attachment of these polymers reduced underlying alloy corrosion rates, but following the salination reaction with physical coating most reduced corrosion rates and protected the surface better from the consequences of oxidation occurring under the coating, such as blistering. The application of a multilayered coating approach using a sulfobetaine-based biodegradable elastomer thus offers options for degradable metallic stent design where thromboresistance is desired in combination with a means to control both polymeric coating degradation rates and underlying alloy corrosion rates.

2.
Ann Biomed Eng ; 47(3): 891-901, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30542784

RESUMO

Although the previous success of bladder tissue engineering demonstrated the feasibility of this technology, most polyester based scaffolds used in previous studies possess inadequate mechanical properties for organs that exhibit large deformation. The present study explored the use of various biodegradable elastomers as scaffolds for bladder tissue engineering and poly (carbonate-urethane) urea (PCUU) scaffolds mimicked urinary bladder mechanics more closely than polyglycerol sebacate-polycaprolactone (PGS-PCL) and poly (ether-urethane) urea (PEUU). The PCUU scaffolds also showed cyto-compatibility as well as increased porosity with increasing stretch indicating its ability to aid in infiltration of smooth muscle cells. Moreover, a bladder outlet obstruction (BOO) rat model was used to test the safety and efficacy of the PCUU scaffolds in treating a voiding dysfunction. Bladder augmentation with PCUU scaffolds led to enhanced survival of the rats and an increase in the bladder capacity and voiding volume over a 3 week period, indicating that the high-pressure bladder symptom common to BOO was alleviated. The histological analysis of the explanted scaffold demonstrated smooth muscle cell and connective tissue infiltration. The knowledge gained in the present study should contribute towards future improvement of bladder tissue engineering technology to ultimately aide in the treatment of bladder disorders.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Obstrução do Colo da Bexiga Urinária , Bexiga Urinária , Animais , Materiais Biocompatíveis , Sobrevivência Celular , Células Cultivadas , Feminino , Miócitos de Músculo Liso , Polímeros , Ratos Sprague-Dawley , Bexiga Urinária/citologia , Bexiga Urinária/fisiologia , Obstrução do Colo da Bexiga Urinária/fisiopatologia
3.
PLoS One ; 13(10): e0205611, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30304058

RESUMO

Polymeric coatings can provide temporary stability to bioresorbable metallic stents at the initial stage of deployment by alleviating rapid degradation and providing better interaction with surrounding vasculature. To understand this interfacing biocompatibility, this study explored the endothelial-cytocompatibility of polymer-coated magnesium (Mg) alloys under static and dynamic conditions compared to that of non-coated Mg alloy surfaces. Poly (carbonate urethane) urea (PCUU) and poly (lactic-co-glycolic acid) (PLGA) were coated on Mg alloys (WE43, AZ31, ZWEKL, ZWEKC) and 316L stainless steel (316L SS, control sample), which were embedded into a microfluidic device to simulate a vascular environment with dynamic flow. The results from attachment and viability tests showed that more cells were attached on the polymer-coated Mg alloys than on non-coated Mg alloys in both static and dynamic conditions. In particular, the attachment and viability on PCUU-coated surfaces were significantly higher than that of PLGA-coated surfaces of WE43 and ZWEKC in both static and dynamic conditions, and of AZ31 in dynamic conditions (P<0.05). The elementary distribution map showed that there were relatively higher Carbon weight percentages and lower Mg weight percentages on PCUU-coated alloys than PLGA-coated alloys. Various levels of pittings were observed underneath the polymer coatings, and the pittings were more severe on the surface of Mg alloys that corroded rapidly. Polymer coatings are recommended to be applied on Mg alloys with relatively low corrosion rates, or after pre-stabilizing the substrate. PCUU-coating has more selective potential to enhance the biocompatibility and mitigate the endothelium damage of Mg alloy stenting.


Assuntos
Implantes Absorvíveis , Materiais Revestidos Biocompatíveis , Células Endoteliais , Magnésio , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Poliuretanos , Ligas , Animais , Encéfalo , Adesão Celular , Sobrevivência Celular , Células Endoteliais/fisiologia , Dispositivos Lab-On-A-Chip , Camundongos , Modelos Cardiovasculares , Aço Inoxidável , Stents , Alicerces Teciduais
4.
Tissue Eng Part A ; 24(11-12): 889-904, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29187125

RESUMO

Ventral hernia is often addressed surgically by the placement of prosthetic materials, either synthetic or from allogeneic and xenogeneic biologic sources. Despite advances in surgical approaches and device design, a number of postsurgical limitations remain, including hernia recurrence, mesh encapsulation, and reduced vascularity of the implanted volume. The in situ controlled release of angiogenic factors from a scaffold facilitating abdominal wall repair might address some of these issues associated with suboptimal tissue reconstruction. Furthermore, a biocomposite material that combines the favorable mechanical properties achievable with synthetic materials and the bioactivity associated with xenogeneic tissue sources would be desirable. In this report, an abdominal wall repair scaffold has been designed based on a microfibrous, elastomeric poly(ester carbonate)urethane urea matrix integrated with a hydrogel derived from decellularized porcine dermis (extracellular matrix [ECM] gel) and poly(lactic-co-glycolic acid) (PLGA) microspheres loaded with nitro-oleic acid (NO2-OA). NO2-OA is an electrophilic fatty acid nitro-alkene derivative that, under hypoxic conditions, induces angiogenesis. This scaffold was utilized to repair a rat abdominal wall partial thickness defect, hypothesizing that the nitro-fatty acid release would facilitate increased angiogenesis at the 8-week endpoint. The quantification of neovascularization was conducted by novel methodologies to assess vessel morphology and spatial distribution. The repaired abdominal wall defects were evaluated by histopathologic methods, including quantification of the foreign body response and cellular ingrowth. The results showed that NO2-OA release was associated with significantly improved regional angiogenesis. The combined biohybrid scaffold and NO2-OA-controlled release strategy also reduced scaffold encapsulation, increased wall thickness, and enhanced cellular infiltration. More broadly, the three components of the composite scaffold design (ECM gel, polymeric fibers, and PLGA microparticles) enable the tuning of performance characteristics, including scaffold bioactivity, degradation, mechanics, and drug release profile, all decisive factors to better address current limitations in abdominal wall repair or other soft tissue augmentation procedures.


Assuntos
Parede Abdominal , Ácido Oleico/uso terapêutico , Animais , Materiais Biocompatíveis , Matriz Extracelular/metabolismo , Neovascularização Fisiológica/efeitos dos fármacos , Ratos
5.
Biomaterials ; 150: 25-37, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29031049

RESUMO

Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality.


Assuntos
Materiais Biocompatíveis/química , Doenças das Valvas Cardíacas/terapia , Medicina Regenerativa/métodos , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Ligas/química , Alumínio/química , Animais , Valva Aórtica/anormalidades , Galvanoplastia/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Valva Mitral/anormalidades , Modelos Animais , Estireno/química , Suínos , Valva Tricúspide/anormalidades
6.
EBioMedicine ; 26: 47-59, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29208469

RESUMO

Central nervous system (CNS) neurons fail to regrow injured axons, often resulting in permanently lost neurologic function. Tacrolimus is an FDA-approved immunosuppressive drug with known neuroprotective and neuroregenerative properties in the CNS. However, tacrolimus is typically administered systemically and blood levels required to effectively treat CNS injuries can lead to lethal, off-target organ toxicity. Thus, delivering tacrolimus locally to CNS tissues may provide therapeutic control over tacrolimus levels in CNS tissues while minimizing off-target toxicity. Herein we show an electrospun poly(ester urethane) urea and tacrolimus elastomeric matrix (PEUU-Tac) can deliver tacrolimus trans-durally to CNS tissues. In an acute CNS ischemia model in rat, the optic nerve (ON) was clamped for 10s and then PEUU-Tac was used as an ON wrap and sutured around the injury site. Tacrolimus was detected in PEUU-Tac wrapped ONs at 24h and 14days, without significant increases in tacrolimus blood levels. Similar to systemically administered tacrolimus, PEUU-Tac locally decreased glial fibrillary acidic protein (GFAP) at the injury site and increased growth associated protein-43 (GAP-43) expression in ischemic ONs from the globe to the chiasm, consistent with decreased astrogliosis and increased retinal ganglion cell (RGC) axon growth signaling pathways. These initial results suggest PEUU-Tac is a biocompatible elastic matrix that delivers bioactive tacrolimus trans-durally to CNS tissues without significantly increasing tacrolimus blood levels and off-target toxicity.


Assuntos
Sistema Nervoso Central/efeitos dos fármacos , Traumatismos do Nervo Óptico/tratamento farmacológico , Células Ganglionares da Retina/efeitos dos fármacos , Tacrolimo/administração & dosagem , Animais , Sistema Nervoso Central/fisiopatologia , Sistemas de Liberação de Medicamentos , Elastômeros/administração & dosagem , Elastômeros/química , Humanos , Traumatismos do Nervo Óptico/patologia , Poliésteres/administração & dosagem , Poliésteres/química , Ratos , Células Ganglionares da Retina/patologia , Tacrolimo/química
7.
J Trauma Acute Care Surg ; 83(2): 249-255, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28452874

RESUMO

BACKGROUND: Noncompressible hemorrhage of the torso remains a challenging surgical dilemma. Stent graft repair requires endovascular expertise, imaging, and inventory that are not available within the critical window of massive hemorrhage. We developed a retrievable stent graft for rapid hemorrhage. We further investigated a radiofrequency (RF) positioning approach as a possible alternative to the logistics of fluoroscopy. METHODS: A retrievable stent graft was constructed with a novel "petal and stem" design from nitinol and covered with a sleeve of electrospun polyurethane. The stent graft was tested using an in vitro model of simulated hemorrhage. Next, the stent graft was examined in vivo using a porcine model of noncompressible hemorrhage. The stent was examined for hemorrhage control in a porcine model of either aortic or caval injury. An RF reader was assembled from an Arduino processor while RF tags were affixed to the ends of the stent graft. Detection accuracy of a handheld RF wand for an RF tag was quantified both in vitro and through tissue. RESULTS: The retrievable RESCUEstent graft was deployed within minutes and rapidly controlled traumatic hemorrhage angiographically in both aortic injury (n = 3) and caval injury (n = 2). Stent grafts were easily recaptured in both models in under 15 seconds. The LED light of a handheld RF detector illuminated when positioned directly over an RF tag. The RF detection approach revealed positioning accuracy to within 1 cm of the intended target, despite tissue interference. CONCLUSION: This study demonstrates the rapid deployment and retrieval of a RESCUE stent graft as well as the ability to tamponade injuries of the aorta and cava. In addition, this study demonstrates the feasibility of RF tags to guide stent placement through tissue. More rigorous models are needed to define the effectiveness of this approach in the setting of vascular injury and shock.


Assuntos
Ligas , Aorta Torácica/lesões , Aorta Torácica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemotórax/cirurgia , Stents , Cirurgia Assistida por Computador/instrumentação , Veia Cava Superior/lesões , Veia Cava Superior/cirurgia , Animais , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Estudos de Viabilidade , Poliuretanos , Suínos
8.
Biomaterials ; 133: 132-143, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28433936

RESUMO

Biodegradable and elastomeric patches have been applied to the surface of infarcted hearts as temporary mechanical supports to effectively alter adverse left ventricular remodeling processes. In this report, recombinant adeno-associated virus (AAV), known for its persistent transgene expression and low pathogenicity, was incorporated into elastomeric polyester urethane urea (PEUU) and polyester ether urethane urea (PEEUU) and processed by electrospinning into two formats (solid fibers and core-sheath fibers) designed to influence the controlled release behavior. The extended release of AAV encoding green fluorescent protein (GFP) was assessed in vitro. Sustained and localized viral particle delivery was achieved over 2 months in vitro. The biodegradable cardiac patches with or without AAV-GFP were implanted over rat left ventricular lesions three days following myocardial infarction to evaluate the transduction effect of released viral vectors. AAV particles were directly injected into the infarcted hearts as a control. Cardiac function and remodeling were significantly improved for 12 weeks after patch implantation compared to AAV injection. More GFP genes was expressed in the AAV patch group than AAV injection group, with both α-SMA positive cells and cardiac troponin T positive cells transduced in the patch group. Overall, the extended release behavior, prolonged transgene expression, and elastomeric mechanical properties make the AAV-loaded scaffold an attractive option for cardiac tissue engineering where both gene delivery and appropriate mechanical support are desired.


Assuntos
Materiais Biocompatíveis/química , Dependovirus/genética , Técnicas de Transferência de Genes , Terapia Genética/métodos , Infarto do Miocárdio/terapia , Animais , Feminino , Vetores Genéticos/efeitos adversos , Vetores Genéticos/genética , Células HEK293 , Ventrículos do Coração/metabolismo , Humanos , Miocárdio/metabolismo , Miocárdio/patologia , Ratos
9.
J Med Eng Technol ; 41(2): 141-150, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27715350

RESUMO

Donation after cardiac death has been adopted to address the critical shortage of donor organs for transplant. Recovery of these organs is hindered by low blood flow that leads to permanent organ injury. We propose a novel approach to isolate the perfusion of the abdominal organs from the systemic malperfusion of the dying donor. We reasoned that this design could improve blood flow to organs without open surgery, while respecting the ethical principle that cardiac stress not be increased during organ recovery. Conditions within the stent were analysed using a computational fluid dynamics (CFD) method and validated on two prototypes in vitro. The hydrodynamic pressure drop across the stent was measured as 0.14-0.22 mmHg, which is a negligible influence. Device placement studies were also conducted on swine model fluoroscopically. All these results demonstrated the feasibility of rapidly isolating the perfusion to abdominal organs using a compartmentalised stent graft design.


Assuntos
Modelos Biológicos , Stents , Transplantes/fisiologia , Transplantes/cirurgia , Animais , Estudos de Viabilidade , Feminino , Humanos , Hidrodinâmica , Perfusão , Projetos Piloto , Suínos , Doadores de Tecidos
10.
Biomaterials ; 107: 1-14, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27579776

RESUMO

As an intervention to abrogate ischemic cardiomyopathy, the concept of applying a temporary, local patch to the surface of the recently infarcted ventricle has been explored from a number of design perspectives. Two important features considered for such a cardiac patch include the provision of appropriate mechanical support and the capacity to influence the remodeling pathway by providing cellular or biomolecule delivery. The objective of this report was to focus on these two features by first evaluating the incorporation of a cardiac extracellular matrix (ECM) component, and second by evaluating the impact of patch anisotropy on the pathological remodeling process initiated by myocardial infarction. The functional outcomes of microfibrous, elastomeric, biodegradable cardiac patches have been evaluated in a rat chronic infarction model. Ten weeks after infarction and 8 wk after patch epicardial placement, echocardiographic function, tissue-level structural remodeling (e.g., biaxial mechanical response and microstructural analysis), and cellular level remodeling were assessed. The results showed that the incorporation of a cardiac ECM altered the progression of several keys aspects of maladaptive remodeling following myocardial infarction. This included decreasing LV global mechanical compliance, inhibiting echocardiographically-measured functional deterioration, mitigating scar formation and LV wall thinning, and promoting angiogenesis. In evaluating the impact of patch anisotropy, no effects from the altered patch mechanics were detected after 8 wk, possibly due to patch fibrous encapsulation. Overall, this study demonstrates the benefit of a cardiac patch design that combines both ventricle mechanical support, through a biodegradable, fibrillary elastomeric component, and the incorporation of ECM-based hydrogel components.


Assuntos
Implantes Absorvíveis , Matriz Extracelular/química , Isquemia Miocárdica/terapia , Poliuretanos/química , Alicerces Teciduais , Disfunção Ventricular Esquerda/terapia , Remodelação Ventricular/fisiologia , Animais , Materiais Biocompatíveis/síntese química , Feminino , Hidrogéis , Teste de Materiais , Isquemia Miocárdica/complicações , Isquemia Miocárdica/patologia , Ratos , Ratos Endogâmicos Lew , Ratos Sprague-Dawley , Recuperação de Função Fisiológica , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/patologia
11.
Surgery ; 160(4): 892-901, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27524434

RESUMO

BACKGROUND: The paradigm for donation after cardiac death subjects donor organs to ischemic injury. A dual-chamber organ perfusion stent would maintain organ perfusion without affecting natural cardiac death. A center lumen allows uninterrupted cardiac blood flow, while an external chamber delivers oxygenated blood to the visceral vessels. METHODS: A prototype organ perfusion stent was constructed from commercial stents. In a porcine model, the organ perfusion stent was deployed, followed by a simulated agonal period. Oxygenated blood perfused the external stent chamber. Organ perfusion was compared between controls (n = 3) and organ perfusion stent (n = 6). Finally, a custom, nitinol, dual chamber organ perfusion stent was fabricated using a retrievable "petal and stem" design. RESULTS: Endovascular organ perfusion stent deployment achieved visceral isolation without adverse impact on cardiac parameters. Visceral oxygen delivery was 4.8-fold greater compared with controls. During the agonal period, organs in organ perfusion stent-treated animals appeared well perfused in contrast with the malperfused controls. A custom nitinol and polyurethane organ perfusion stent was recaptured easily with simple sheath advancement. CONCLUSION: An organ perfusion stent maintained organ perfusion during the agonal phase in a porcine model of donation after cardiac death organ donation without adversely affecting cardiac function. Ultimately, the custom retrievable design of this study may help resolve the critical shortage of donor organs for transplant.


Assuntos
Morte , Rejeição de Enxerto/prevenção & controle , Preservação de Órgãos/métodos , Perfusão/instrumentação , Stents , Animais , Circulação Coronária , Modelos Animais de Doenças , Sobrevivência de Enxerto , Transplante de Rim/métodos , Transplante de Fígado/métodos , Perfusão/métodos , Traumatismo por Reperfusão/prevenção & controle , Medição de Risco , Sensibilidade e Especificidade , Suínos , Obtenção de Tecidos e Órgãos
12.
J Clin Neurosci ; 30: 39-43, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27234606

RESUMO

Lumbar disc herniation is usually managed with conservative treatment or surgery. However, conservative therapy seldom yields good results, and surgery is associated with multiple complications. This study aimed to assess bipolar radiofrequency thermocoagulation for the treatment of lumbar disc herniation. A total of 168 patients with lumbar disc herniation suitable for radiofrequency thermocoagulation were enrolled and randomized to monopolar radiofrequency thermocoagulation (control group, n=84) or bipolar radiofrequency thermocoagulation (experimental group, n=84) treatment groups. Ablation sites were targeted under CT scan guidance, and consecutive radiofrequency therapy was used. One and two probes were used for monopolar and bipolar thermocoagulation, respectively. Thermocoagulation was achieved at 50°C, 60°C, and 70°C for 60s each, 80°C for 90s, and 92°C for 100s. Symptoms and complications were evaluated using the modified Macnab criteria and Visual Analog Scale at 7, 30, and 180days postoperatively. At 180days, a significantly higher efficacy rate was obtained in the experimental group compared with control patients (91.6% versus 79.7%, P<0.05). No severe complications were occurred in either group. Targeted ablation via bipolar radiofrequency thermocoagulation is efficient for lumbar disc herniation treatment, and should be further explored for broad clinical application.


Assuntos
Eletrocoagulação/métodos , Deslocamento do Disco Intervertebral/cirurgia , Adulto , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Resultado do Tratamento
13.
Colloids Surf B Biointerfaces ; 144: 170-179, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27085049

RESUMO

Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents.


Assuntos
Doenças Cardiovasculares/terapia , Materiais Revestidos Biocompatíveis/farmacologia , Stents Farmacológicos , Magnésio/farmacologia , Polímeros/farmacologia , Ligas , Animais , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Elastômeros , Íons , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/efeitos dos fármacos , Ratos , Ovinos , Propriedades de Superfície , Microtomografia por Raio-X
14.
J Med Eng Technol ; 40(4): 186-98, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27004923

RESUMO

This study proposed a novel ventriculoamniotic shunt device for foetal aqueductal stenosis treatment fabricated with 3Fr or 4Fr size catheters that have a longitudinal bending stiffness with kink resistance, sufficient luminal area for cerebrospinal fluid drainage and capacity for valve integration. Computational flow dynamics studies were carried out to optimise the device design, including size of the lumen and length of the device. An in vitro pressure and flow rate measurement test circuit was constructed to assess the high pressure relieving functionality of draining cerebrospinal fluid from foetal brain. Additionally, a resistance force measurement test platform was built to quantitatively evaluate the anchor performance of various geometric designs. The valve functionality was qualitatively evaluated through the visualisation of the flow patterns in the amniotic sac with injected red coloured fluid under stereomicroscopy. These in vitro results demonstrate the feasibility of the ventriculoamniotic shunt device designed for placement in the foetal brain.


Assuntos
Derivações do Líquido Cefalorraquidiano/métodos , Hidrocefalia/cirurgia , Feminino , Feto , Análise de Elementos Finitos , Humanos , Gravidez
15.
Biomacromolecules ; 12(8): 3066-77, 2011 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-21675705

RESUMO

In this Article, we studied the enzymatic hydrolytic biodegradation behavior of a novel multiblock thermoplastic polyurethane (TPU) system, which incorporates polyhedral oligomeric silsesquioxane (POSS) into linear biodegradable thermoplastic polyurethanes containing poly(ε-caproactone) (PCL) and polyethylene glycol (PEG) blocks. The biodegradation behavior of POSS-PCL-PEG TPUs was characterized by proton nuclear magnetic resonance spectroscopy ((1)H NMR), differential scanning calorimetry (DSC), tensile tests, scanning electron microscopy (SEM), and wavelength dispersive X-ray spectrometry (WDS) after enduring 22-day accelerated enzymatic hydrolytic degradation tests. POSS incorporation significantly suppressed in vitro enzymatic hydrolytic degradation of PCL-PEG-based multiblock TPUs by a surface passivation mechanism. WDS observations revealed that the covalently bonded POSS moieties developed a near-continuous and robust POSS-layer after initial degradation, which prevented ester bonds of PCL from enzymatic attack, thereby inhibiting further degradation. These striking results provide a new strategy to fabricate the polyester-based biostable thermoplastic polyurethanes (TPUs) of potential use in long-term surgical implants.


Assuntos
Compostos de Organossilício/química , Poliuretanos/química , Varredura Diferencial de Calorimetria , Cromatografia em Gel , Hidrólise , Espectroscopia de Ressonância Magnética , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...